强生爱惜康Ethicon Gen11高频套装维修更换
品牌名称:强生爱惜康Ethicon
维修类型:高频套装维修
维修型号:Gen11
详细配置与设备参数:
GEN11 Endo-Surgery generator combines advanced technology, multifunctionality and touchscreen simplicity in one sleek and easy-to-operate unit. No matter what the procedure or which Ethicon device you plan to use, the Ethicon Endo-Surgery generator will be the only power source you’ll need. This unit supports Harmonic Ultrasonic and Enseal Advanced Bipolar Devices.
Universal connector and automatic instrument recognition.
Touchscreen for easy setup and operation.
High-resolution display with wider viewing angles.
Compact design takes up less space in the OR.
Software updates available via USB memory stick.

维修项目:
1.更钳头修复绝缘部分;
2.修复或更换钳芯;
3.维修或更换连接线缆
4.更换操作手柄
常见故障:
1.钳头故障,绝缘缺失;
2.钳芯断裂或导电性差;
3.连接线缆断裂,无法识别器械;
4.操作手柄损坏,不可操作;
相关维修设备与配件:
史赛克Stryker TPS通用驱动程序 设备编号:5100-99
史赛克Stryker CORE™通用驱动程序 设备编号:5400-99
史赛克Stryker RemB™通用驱动器 设备编号:6400-099
史赛克Stryker TPS微型钻 设备编号:5100-15
史赛克Stryker CORE™微钻 设备编号:5400-15
WOLF狼牌 8871.413 30°关节镜维修
Olympus奥林巴斯CF-P20肠镜维修
R.wolf狼牌8860.433关节镜维修